Class SPI
- All Implemented Interfaces:
AutoCloseable
public class SPI extends Object implements AutoCloseable
-
Nested Class Summary
-
Constructor Summary
-
Method Summary
Modifier and Type Method Description void
close()
void
configureAutoStall(int csToSclkTicks, int stallTicks, int pow2BytesPerRead)
Configure the Auto SPI Stall time between reads.void
forceAutoRead()
Force the engine to make a single transfer.void
freeAccumulator()
Frees the accumulator.void
freeAuto()
Frees the automatic SPI transfer engine.double
getAccumulatorAverage()
Read the average of the accumulated value.int
getAccumulatorCount()
Read the number of accumulated values.double
getAccumulatorIntegratedAverage()
Read the average of the integrated value.double
getAccumulatorIntegratedValue()
Read the integrated value.int
getAccumulatorLastValue()
Read the last value read by the accumulator engine.void
getAccumulatorOutput(AccumulatorResult result)
Read the accumulated value and the number of accumulated values atomically.long
getAccumulatorValue()
Read the accumulated value.int
getAutoDroppedCount()
Get the number of bytes dropped by the automatic SPI transfer engine due to the receive buffer being full.int
getPort()
void
initAccumulator(double period, int cmd, int xferSize, int validMask, int validValue, int dataShift, int dataSize, boolean isSigned, boolean bigEndian)
Initialize the accumulator.void
initAuto(int bufferSize)
Initialize automatic SPI transfer engine.int
read(boolean initiate, byte[] dataReceived, int size)
Read a word from the receive FIFO.int
read(boolean initiate, ByteBuffer dataReceived, int size)
Read a word from the receive FIFO.int
readAutoReceivedData(int[] buffer, int numToRead, double timeout)
Read data that has been transferred by the automatic SPI transfer engine.int
readAutoReceivedData(ByteBuffer buffer, int numToRead, double timeout)
Read data that has been transferred by the automatic SPI transfer engine.void
resetAccumulator()
Resets the accumulator to zero.void
setAccumulatorCenter(int center)
Set the center value of the accumulator.void
setAccumulatorDeadband(int deadband)
Set the accumulator's deadband.void
setAccumulatorIntegratedCenter(double center)
Set the center value of the accumulator integrator.void
setAutoTransmitData(byte[] dataToSend, int zeroSize)
Set the data to be transmitted by the engine.void
setChipSelectActiveHigh()
Configure the chip select line to be active high.void
setChipSelectActiveLow()
Configure the chip select line to be active low.void
setClockRate(int hz)
Configure the rate of the generated clock signal.void
setMode(SPI.Mode mode)
Sets the mode for the SPI device.void
startAutoRate(double period)
Start running the automatic SPI transfer engine at a periodic rate.void
startAutoTrigger(DigitalSource source, boolean rising, boolean falling)
Start running the automatic SPI transfer engine when a trigger occurs.void
stopAuto()
Stop running the automatic SPI transfer engine.int
transaction(byte[] dataToSend, byte[] dataReceived, int size)
Perform a simultaneous read/write transaction with the device.int
transaction(ByteBuffer dataToSend, ByteBuffer dataReceived, int size)
Perform a simultaneous read/write transaction with the device.int
write(byte[] dataToSend, int size)
Write data to the peripheral device.int
write(ByteBuffer dataToSend, int size)
Write data to the peripheral device.
-
Constructor Details
-
SPI
Constructor.- Parameters:
port
- the physical SPI port
-
-
Method Details
-
getPort
-
close
- Specified by:
close
in interfaceAutoCloseable
-
setClockRate
Configure the rate of the generated clock signal. The default value is 500,000 Hz. The maximum value is 4,000,000 Hz.- Parameters:
hz
- The clock rate in Hertz.
-
setMode
Sets the mode for the SPI device.Mode 0 is Clock idle low, data sampled on rising edge.
Mode 1 is Clock idle low, data sampled on falling edge.
Mode 2 is Clock idle high, data sampled on falling edge.
Mode 3 is Clock idle high, data sampled on rising edge.
- Parameters:
mode
- The mode to set.
-
setChipSelectActiveHigh
Configure the chip select line to be active high. -
setChipSelectActiveLow
Configure the chip select line to be active low. -
write
Write data to the peripheral device. Blocks until there is space in the output FIFO.If not running in output only mode, also saves the data received on the CIPO input during the transfer into the receive FIFO.
- Parameters:
dataToSend
- The buffer containing the data to send.size
- The number of bytes to send.- Returns:
- Number of bytes written or -1 on error.
-
write
Write data to the peripheral device. Blocks until there is space in the output FIFO.If not running in output only mode, also saves the data received on the CIPO input during the transfer into the receive FIFO.
- Parameters:
dataToSend
- The buffer containing the data to send.size
- The number of bytes to send.- Returns:
- Number of bytes written or -1 on error.
-
read
Read a word from the receive FIFO.Waits for the current transfer to complete if the receive FIFO is empty.
If the receive FIFO is empty, there is no active transfer, and initiate is false, errors.
- Parameters:
initiate
- If true, this function pushes "0" into the transmit buffer and initiates a transfer. If false, this function assumes that data is already in the receive FIFO from a previous write.dataReceived
- Buffer in which to store bytes read.size
- Number of bytes to read.- Returns:
- Number of bytes read or -1 on error.
-
read
Read a word from the receive FIFO.Waits for the current transfer to complete if the receive FIFO is empty.
If the receive FIFO is empty, there is no active transfer, and initiate is false, errors.
- Parameters:
initiate
- If true, this function pushes "0" into the transmit buffer and initiates a transfer. If false, this function assumes that data is already in the receive FIFO from a previous write.dataReceived
- The buffer to be filled with the received data.size
- The length of the transaction, in bytes- Returns:
- Number of bytes read or -1 on error.
-
transaction
Perform a simultaneous read/write transaction with the device.- Parameters:
dataToSend
- The data to be written out to the devicedataReceived
- Buffer to receive data from the devicesize
- The length of the transaction, in bytes- Returns:
- TODO
-
transaction
Perform a simultaneous read/write transaction with the device.- Parameters:
dataToSend
- The data to be written out to the device.dataReceived
- Buffer to receive data from the device.size
- The length of the transaction, in bytes- Returns:
- TODO
-
initAuto
Initialize automatic SPI transfer engine.Only a single engine is available, and use of it blocks use of all other chip select usage on the same physical SPI port while it is running.
- Parameters:
bufferSize
- buffer size in bytes
-
freeAuto
Frees the automatic SPI transfer engine. -
setAutoTransmitData
Set the data to be transmitted by the engine.Up to 16 bytes are configurable, and may be followed by up to 127 zero bytes.
- Parameters:
dataToSend
- data to send (maximum 16 bytes)zeroSize
- number of zeros to send after the data
-
startAutoRate
Start running the automatic SPI transfer engine at a periodic rate.initAuto(int)
andsetAutoTransmitData(byte[], int)
must be called before calling this function.- Parameters:
period
- period between transfers, in seconds (us resolution)
-
startAutoTrigger
Start running the automatic SPI transfer engine when a trigger occurs.initAuto(int)
andsetAutoTransmitData(byte[], int)
must be called before calling this function.- Parameters:
source
- digital source for the trigger (may be an analog trigger)rising
- trigger on the rising edgefalling
- trigger on the falling edge
-
stopAuto
Stop running the automatic SPI transfer engine. -
forceAutoRead
Force the engine to make a single transfer. -
readAutoReceivedData
Read data that has been transferred by the automatic SPI transfer engine.Transfers may be made a byte at a time, so it's necessary for the caller to handle cases where an entire transfer has not been completed.
Each received data sequence consists of a timestamp followed by the received data bytes, one byte per word (in the least significant byte). The length of each received data sequence is the same as the combined size of the data and zeroSize set in setAutoTransmitData().
Blocks until numToRead words have been read or timeout expires. May be called with numToRead=0 to retrieve how many words are available.
- Parameters:
buffer
- buffer where read words are storednumToRead
- number of words to readtimeout
- timeout in seconds (ms resolution)- Returns:
- Number of words remaining to be read
-
readAutoReceivedData
Read data that has been transferred by the automatic SPI transfer engine.Transfers may be made a byte at a time, so it's necessary for the caller to handle cases where an entire transfer has not been completed.
Each received data sequence consists of a timestamp followed by the received data bytes, one byte per word (in the least significant byte). The length of each received data sequence is the same as the combined size of the data and zeroSize set in setAutoTransmitData().
Blocks until numToRead words have been read or timeout expires. May be called with numToRead=0 to retrieve how many words are available.
- Parameters:
buffer
- array where read words are storednumToRead
- number of words to readtimeout
- timeout in seconds (ms resolution)- Returns:
- Number of words remaining to be read
-
getAutoDroppedCount
Get the number of bytes dropped by the automatic SPI transfer engine due to the receive buffer being full.- Returns:
- Number of bytes dropped
-
configureAutoStall
Configure the Auto SPI Stall time between reads.- Parameters:
csToSclkTicks
- the number of ticks to wait before asserting the cs pinstallTicks
- the number of ticks to stall forpow2BytesPerRead
- the number of bytes to read before stalling
-
initAccumulator
public void initAccumulator(double period, int cmd, int xferSize, int validMask, int validValue, int dataShift, int dataSize, boolean isSigned, boolean bigEndian)Initialize the accumulator.- Parameters:
period
- Time between readscmd
- SPI command to send to request dataxferSize
- SPI transfer size, in bytesvalidMask
- Mask to apply to received data for validity checkingvalidValue
- After validMask is applied, required matching value for validity checkingdataShift
- Bit shift to apply to received data to get actual data valuedataSize
- Size (in bits) of data fieldisSigned
- Is data field signed?bigEndian
- Is device big endian?
-
freeAccumulator
Frees the accumulator. -
resetAccumulator
Resets the accumulator to zero. -
setAccumulatorCenter
Set the center value of the accumulator.The center value is subtracted from each value before it is added to the accumulator. This is used for the center value of devices like gyros and accelerometers to make integration work and to take the device offset into account when integrating.
- Parameters:
center
- The accumulator's center value.
-
setAccumulatorDeadband
Set the accumulator's deadband.- Parameters:
deadband
- The accumulator's deadband.
-
getAccumulatorLastValue
Read the last value read by the accumulator engine.- Returns:
- The last value read by the accumulator engine.
-
getAccumulatorValue
Read the accumulated value.- Returns:
- The 64-bit value accumulated since the last Reset().
-
getAccumulatorCount
Read the number of accumulated values.Read the count of the accumulated values since the accumulator was last Reset().
- Returns:
- The number of times samples from the channel were accumulated.
-
getAccumulatorAverage
Read the average of the accumulated value.- Returns:
- The accumulated average value (value / count).
-
getAccumulatorOutput
Read the accumulated value and the number of accumulated values atomically.This function reads the value and count atomically. This can be used for averaging.
- Parameters:
result
- AccumulatorResult object to store the results in.
-
setAccumulatorIntegratedCenter
Set the center value of the accumulator integrator.The center value is subtracted from each value*dt before it is added to the integrated value. This is used for the center value of devices like gyros and accelerometers to take the device offset into account when integrating.
- Parameters:
center
- The accumulator integrator's center value.
-
getAccumulatorIntegratedValue
Read the integrated value. This is the sum of (each value * time between values).- Returns:
- The integrated value accumulated since the last Reset().
-
getAccumulatorIntegratedAverage
Read the average of the integrated value. This is the sum of (each value times the time between values), divided by the count.- Returns:
- The average of the integrated value accumulated since the last Reset().
-