Contains functions for roboRIO functionality.
-
Method Summary
Modifier and Type Method Description static double
getBatteryVoltage()
Read the battery voltage.static double
getBrownoutVoltage()
Get the current brownout voltage setting.static CANStatus
getCANStatus()
Get the current status of the CAN bus.static double
getCurrent3V3()
Get the current output of the 3.3V rail.static double
getCurrent5V()
Get the current output of the 5V rail.static double
getCurrent6V()
Get the current output of the 6V rail.static boolean
getEnabled3V3()
Get the enabled state of the 3.3V rail.static boolean
getEnabled5V()
Get the enabled state of the 5V rail.static boolean
getEnabled6V()
Get the enabled state of the 6V rail.static int
getFaultCount3V3()
Get the count of the total current faults on the 3.3V rail since the controller has booted.static int
getFaultCount5V()
Get the count of the total current faults on the 5V rail since the controller has booted.static int
getFaultCount6V()
Get the count of the total current faults on the 6V rail since the controller has booted.static long
getFPGARevision()
Return the FPGA Revision number.static long
getFPGATime()
Read the microsecond timer from the FPGA.static int
getFPGAVersion()
Return the FPGA Version number.static double
getInputCurrent()
Get the input current to the robot controller.static double
getInputVoltage()
Get the input voltage to the robot controller.static String
getSerialNumber()
Return the serial number of the roboRIO.static boolean
getUserButton()
Get the state of the "USER" button on the roboRIO.static double
getVoltage3V3()
Get the voltage of the 3.3V rail.static double
getVoltage5V()
Get the voltage of the 5V rail.static double
getVoltage6V()
Get the voltage of the 6V rail.static boolean
isBrownedOut()
Check if the system is browned out.static boolean
isSysActive()
Gets a value indicating whether the FPGA outputs are enabled.static void
setBrownoutVoltage(double brownoutVoltage)
Set the voltage the roboRIO will brownout and disable all outputs.
-
Method Details
-
getFPGAVersion
Return the FPGA Version number. For now, expect this to be the current year.- Returns:
- FPGA Version number.
-
getFPGARevision
Return the FPGA Revision number. The format of the revision is 3 numbers. The 12 most significant bits are the Major Revision. the next 8 bits are the Minor Revision. The 12 least significant bits are the Build Number.- Returns:
- FPGA Revision number.
-
getSerialNumber
Return the serial number of the roboRIO.- Returns:
- The serial number of the roboRIO.
-
getFPGATime
Read the microsecond timer from the FPGA.- Returns:
- The current time in microseconds according to the FPGA.
-
getUserButton
Get the state of the "USER" button on the roboRIO.- Returns:
- true if the button is currently pressed down
-
getBatteryVoltage
Read the battery voltage.- Returns:
- The battery voltage in Volts.
-
isSysActive
Gets a value indicating whether the FPGA outputs are enabled. The outputs may be disabled if the robot is disabled or e-stopped, the watchdog has expired, or if the roboRIO browns out.- Returns:
- True if the FPGA outputs are enabled.
-
isBrownedOut
Check if the system is browned out.- Returns:
- True if the system is browned out
-
getInputVoltage
Get the input voltage to the robot controller.- Returns:
- The controller input voltage value in Volts
-
getInputCurrent
Get the input current to the robot controller.- Returns:
- The controller input current value in Amps
-
getVoltage3V3
Get the voltage of the 3.3V rail.- Returns:
- The controller 3.3V rail voltage value in Volts
-
getCurrent3V3
Get the current output of the 3.3V rail.- Returns:
- The controller 3.3V rail output current value in Amps
-
getEnabled3V3
Get the enabled state of the 3.3V rail. The rail may be disabled due to a controller brownout, a short circuit on the rail, or controller over-voltage.- Returns:
- The controller 3.3V rail enabled value
-
getFaultCount3V3
Get the count of the total current faults on the 3.3V rail since the controller has booted.- Returns:
- The number of faults
-
getVoltage5V
Get the voltage of the 5V rail.- Returns:
- The controller 5V rail voltage value in Volts
-
getCurrent5V
Get the current output of the 5V rail.- Returns:
- The controller 5V rail output current value in Amps
-
getEnabled5V
Get the enabled state of the 5V rail. The rail may be disabled due to a controller brownout, a short circuit on the rail, or controller over-voltage.- Returns:
- The controller 5V rail enabled value
-
getFaultCount5V
Get the count of the total current faults on the 5V rail since the controller has booted.- Returns:
- The number of faults
-
getVoltage6V
Get the voltage of the 6V rail.- Returns:
- The controller 6V rail voltage value in Volts
-
getCurrent6V
Get the current output of the 6V rail.- Returns:
- The controller 6V rail output current value in Amps
-
getEnabled6V
Get the enabled state of the 6V rail. The rail may be disabled due to a controller brownout, a short circuit on the rail, or controller over-voltage.- Returns:
- The controller 6V rail enabled value
-
getFaultCount6V
Get the count of the total current faults on the 6V rail since the controller has booted.- Returns:
- The number of faults
-
getBrownoutVoltage
Get the current brownout voltage setting.- Returns:
- The brownout voltage
-
setBrownoutVoltage
Set the voltage the roboRIO will brownout and disable all outputs.Note that this only does anything on the roboRIO 2. On the roboRIO it is a no-op.
- Parameters:
brownoutVoltage
- The brownout voltage
-
getCANStatus
Get the current status of the CAN bus.- Returns:
- The status of the CAN bus
-